Clean Tech 2011

Milano – 13/14 ottobre 2011
Il controllo della contaminazione all’interno della clean room del terzo millennio: evoluzione tecnologica, livelli qualitativi, sostenibilità & economicità

Milano 13 Ottobre – SESSIONE PLENARIA

TC209: overall overview (relazione in inglese)
B. Milke

  • Introduction
  • History
  • TC Organization and Structure
  • Writing a Standard
  • Current Activities in TC 209

Review of the status and impact of the revision of ISO 14644-1 & 2 (relazione in inglese)
G. Farquharson

  • ISO 14644/1: change and impact
    – the basis for classification
    – the 95% UCL evaluation
    – sample locations
    – sequential sampling
    – ultrafine descriptor
    – test methods
  • ISO 14644/2: change and impact
    – Table of test frequencies
    – Real-time monitoring systems

How to qualify or certify a controlled environment according to ISO 14644/3 (relazione in inglese)
D. Brande

  • Why Certification
  • Filter Integrity
  • Pressure
  • Air Volumes
  • Airflow Visualization
  • Room Classification

Introduction on the new Chinese standard on GMP and cleanroom. Introduction to super large cleanrooms in microelectronics (relazione in inglese)
W. Da Qian

  • Chinese GMP-2010 new version
  • Super large cleanroom and test
  • Internationalization of national cleanroom standards

The development of operating rooms in Europe (relazione in inglese)
B. Ljungqvist

  • Ventilation in operating rooms around 1960
  • Charnley’s original system
  • Ventilation systems

Performance test and the new italian standard for operating rooms (relazione in inglese)
C. Joppolo – C. Rossi – F. Romano

  • Ventilation in hospitals
  • Ventilation and contamination control
  • The new italian standard UNI
  • Ventilation and conditioning system for contamination control
  • Some final points

SESSIONE PARALLELA A – Gli ambienti a contaminazione controllata in ambito farmaceutico

Controllo della contaminazione e contenimento di sostanze attive: criteri progettuali, strategie e casi di studio
P.A. Galligani

  • Introduzione
  • Le matrici di controllo
  • Porcedure di valutazione del processo
  • Contenimento e cross-contamination
  • Contenimento primario e secondario
  • Esempi pratici

Come si può trasferire in area sterile un materiale sensibile al calore controllandone la bio-contaminazione superficiale? Esponiamolo ad un biocida ossidante in forma gassosa
S. Mauri

  • La decontaminazione microbica superficiale
  • I vettori della contaminazione biologica
  • Valutazione del rischio
  • Decontaminazione vs sterilizzazione
  • Panorama normativo
  • Il processo di decontaminazione
    – scelta del biocida
    – fasi del ciclo
    – convalida del processo

Case history: applicazione della tecnologia degli isolatori per la produzione in asepsi di farmaci sterili
M. Ammannito – E. Moia

  • Lo stabilimento
    – il processo produttivo
    – la scelta della tecnologia impiantistica: l’isolatore
    – il progetto
  • Impianti critici: gli impianti HVAC
  • Risultati dei controlli della contaminazione nell’isolatore

Impianti farmaceutici complessi: nuove frontiere del contenimento e del risparmio energetico
E. Moia

  • Introduzione
  • Panorama normativo
  • Aspetti topici di un impianto
  • Soluzioni per un risparmio energetico

Applicazione della QbD nei controlli ambientali microbiologici
G. Dalmaso

  • Il mercato dei prodotti farmaceutici
  • Test microbiologici correnti e prodotti
  • Metodi di microbiologia rapida
    – le tecnologie
    – i vantaggi
  • Approccio di un’azienda farmaceutica

SESSIONE PARALLELA B – Gli ambienti a contaminazione controllata in ambito ospedaliero

Energy recovery in HVAC systems for operating theatres: LCC analysis (relazione in inglese)
R. Basso – C. Jeandenant

  • Introduction
  • Design of the air diffusion and air filtration system
  • Qualification of surgery room
  • Comparison of different system with LCC calculation

The microbiological air and surface monitoring in operating room (relazione in inglese)
Z. Dalla Valle – R. Ligugnana – L. Whittard

  • Introduction
  • Guidilines for microbiological environmental monitoring in operating theatre
  • Surface sampling
  • Active air sampling
  • How to chose a suitable air sampler

Cleanrooms and clean zones in hospital (relazione in inglese)
A. Fedotov

  • Disaster for patients
  • Hospital infections: history of protection
  • Criteria for protection against infections
  • Particles and microorganisms in air
  • Sources of microbial contamination
  • Protective measures
  • Russian standard GOST R 52539

Swedish Survey and a summary of investigations in operating rooms (relazione in inglese)
J. Nordenadler

  • Application of the dilution principle
  • Source strenght
  • Study in a test chamber

Clothing systems in operating rooms (relazione in inglese)
B. Reinmüller

  • Bacteria in the hospital environment
  • The number of airborne CFUs in the operating room
  • Compared clothing systems

La formazione quale barriera primaria di protezione del personale
P. Parrello

  • Sicurezza e fattore umano
  • La percezione del rischio ed errori umani
  • La formazione

Milano 14 Novembre – SESSIONE PLENARIA

Sustainable cleanroom technology. Energy saving and application the EN 16001 standard (relazione in inglese)
G. Farquharson

  • Why focus on HVAC and environmental control?
  • Energy standards
  • Air handling systems configuration
  • Low energy component selection
  • Function & operation
  • The challenges of complexity
  • GMP impact

IEST Recommended Practices as supplements to the ISO Cleanroom Standards (relazione in inglese)
B. Mielke

  • Introduction
  • IEST History
  • IEST Recommended Practices

Tendenze del controllo microbiologico in clean room e revisione nelle norme ISO 14698
M. Magrì

Conteggio delle particelle aeroportate: considerazione sulla scelta dei punti di campionamento
J. Gecsey

  • Particle counting applications: classification and monitoring
  • Number of sample probes for monitoring
  • Placement of sample probes
  • Selecting monitoring positions

Impianti a contaminazione controllata per la produzione di medicinali per terapie avanzate
L. Sabatini

  • Le terapie avanzate
  • Panorama normativo
  • Definizione dei criteri di progettazione adottati
  • Applicazione dei requisiti di progetto

SESSIONE PARALLELA A – GLI AMBIENTI A CONTAMINAZIONE CONTROLLATA IN AMBITO FARMACEUTICO

Air cleanliness for sterile production: requirements, practice and further progress (relazione in inlgese)
A. Fedotov

  • Differences between EU and FDA
  • Particle ≥ 5.0 μm
  • Aseptic and terminal sterilization
  • Discussion and proposals

Which Biological lndicator better fits different biodecontamination process as hydrogen peroxide vapours, peracetic acid and chlorine dioxide? Use of Bl’s when qualifying a new system (relazione in inglese)
G. Krushefski

  • Appropriate selection of biological indicators
  • Lethality studies
  • Using multiple BIs
  • Statistical evaluation of the results obtained

Modular cleanroom design and ISO 14644-4 for GMP cleanrooms (relazione in inglese)
C. Murray

  • Introduction to ISO 14644 Standards
  • GMP & ISO 14644-­‐4 Standard
  • Modular GMP Cleanroom Design
  • Examples of Modular GMP Cleanrooms
  • Case Study -­ EU Tissue Directive

Isolated Aseptic Robotics; Integration Strategies and Lean Manufacturing (relazione in inglese)
C. Procyshyn

  • Injectable drugs vs human factor
  • Comparison semicon vs biopharma
  • Isolation Technology
  • The new challenge: robotic

SESSIONE PARALLELA B – Le nuove tecnologie e il concetto di sostenibilità nelle clean room del terzo millennio

Examples of sustainable design of utilities and HVAC in modern pharma plants (relazione in inglese)
B. Bagatta – A. Bernardis

  • Sustainability applied to the pharmaceutical world
  • How is sustainability applied
  • Case study
    – Consideration about pre-heating
    – Consideration about post-heating
  • Economics & environmental summary

La camera bianca del Politecnico: un laboratorio per prove sperimentali, ricerche e corsi professionali
C.M. Joppolo – F. Romano – C. Rossi – L. Sabatini

Criteri di efficienza Energetica nella progettazione delle cleanrooms
M. Lucentini – L. Summa

  • Aspetti progettuali oggetto di ricerca
  • Basse cadute di pressione nel sistema di circolazione dell’aria
  • Numero di ricambi d’aria (ACRs, Air ChangeRates)
  • Aumento della percentuale di aria di ricircolo
  • Soluzioni di ricircolo per il sistema HVAC
  • Ottimizzazione della superficie filtrante
  • Ottimizzazione del sistema ventilante
  • Ottimizzazione del sistema di refrigerazione dell’acqua

A test method and experimental assessment of microbiological air sampler efficiency in cleanrooms
F. Romano – C. Joppolo – L. Sabatini

  • Actual sampling techniques of biological airborne contaminants
  • Test procedure
  • Experimental tests

Indoor Air Control in HVAC systems per ottimizzare costi energetici e di conformità regolatoria
D. Zucchelli

  • Modello per la gestione della qualità dell’aria
  • Analisi del rischio
  • Requisiti del sistema
  • La gestione della qualità dell’aria
  • Costo del Ciclo di vita per i filtri aria e suo calcolo

On the sampling efficiency of a single stage centrifugal microbiological air sampler: theoretical and experimental approach (relazione in inglese)
L. Sabatini – F. Romano – C. Joppolo

  • Principle function
  • Theoretical model
  • Experimental test layout
  • Results and discussions